pump noise, noise pollution, noise exposureAbstract
Considering industrial excessive noise exposure, sound pressure level of 4 pumps with different applications installed in Isomax Unit of Oil Refinery Centre of Tehran, Iran was studied. The A-weighted sound pressure level and maximum sound pressure level showed that the emitted noise is far above the permissible limits. Installing enclosure around the noise source was found to be the best noise control measure. Results of operational calculating transmission loss of the designed module with a sandwich layer showed that it is possible to provide 19.7 dB (A) reduction in overall sound pressure level and 20 dB reduction in dominant frequency. Designing the module with given specifications and probable leak estimation and prevention gives remarkable and effective results in the studied field.