VIBRATION MONITORING AND FAULT DIAGNOSIS OF AN I.D.FAN AT A CEMENT PLANT
Keywords:
Vibration monitoring, Cement plant, Mechanical coupling, Rotating machinery.Abstract
I.D.fan (Kiln) of a Cement plant consisting of a motor, two mechanical couplings, a hydraulic coupling and a heavy
fan (approx. two tons) was giving high vibrations at some locations. This was monitored at all the bearing locations
and its vibration symptoms were recorded for analysis purpose. Frequency domain and phase analysis were made to
diagnose the root cause of vibrations. On the basis of this analysis, fault observed was mainly with the fluid coupling.
The vibration spectra and phase data are presented in this paper.
Downloads
Published
2003-08-25
How to Cite
Hafeez, T., Ahmed, A., Chohan, G. Y., & Amir, M. (2003). VIBRATION MONITORING AND FAULT DIAGNOSIS OF AN I.D.FAN AT A CEMENT PLANT. Biological Sciences - PJSIR, 46(4), 225–229. Retrieved from https://v2.pjsir.org/index.php/biological-sciences/article/view/1637
Issue
Section
Articles